BASIC PLASTERS GYPSUM-LIME
RENOFIX 90 THOROUGH PROCESSING AND INTERIOR AREAS FELTING MORTAR

To be used as a basic felt plaster for internal areas. It is not for use in wet/moist areas. For manual plastering one sack of Renofix 90 is mixed with 9 to 10 litres of clean water for approximately 2 minutes and then spread with sand. The 5kure-Tech 5-4 is used for machine plastering and levelled using an aluminium leveller. Mini­mum thickness is 10 mm for the walls and 7 mm for ceilings. The minimum func­tional temperature is 5°C.

Technical InstructionSecurity ListStatement of PropertiesShow All
RENOFIX 100 THOROUGH PLASTERING AND SMOOTHING MORTAR FOR INTERIOR AREAS

To be used as a basic sand plaster and sand layer for internal surfaces. It is not sui­table for wet/moist surfaces. One sack Renofix 100 is mixed with 10 to 11 litres of pure clean water. The 5kure-Tech 5-4 is used for machine plastering and levelled using an aluminium leveller. Minimum thickness is 10 mm for the walls and 7 mm for the ceilings. The minimum functional temperature is 5°C.

Technical InstructionSecurity ListStatement of PropertiesShow All
RENOFIX 200 SMOOTHING MATERIAL FOR LEVELING INTERIOR WALLS AND CEILINGS

The mixture for sanding walls previously plastered or constructed from gypsum plas­terboard. One sack Renofix 200 is mixed in 12-13 litres of water. Remains able to be spread for 40 to 50 minutes. The thickness of the plaster should be 1-5 mm. The wall plastered with Renofix 200 allows for 2,5% moisture, but before applying wall­paper or colour must be completely dry. The minimum functional temperature is 5°C.

Technical InstructionSecurity ListStatement of PropertiesShow All
RENOFIX 202 LEVELING MASS APPLIED ON A LIME BASE

The mixture for sanding walls previously plastered or constructed from gypsum plas­terboard. One sack Renofix 200 is mixed in 12-13 litres of water. Remains able to be spread for 40 to 50 minutes. The thickness of the plaster should be 1-5 mm. The wall plastered with Renofix 200 allows for 2,5% moisture, but before applying wall­paper or colour must be completely dry. The minimum functional temperature is 5°C.

Technical InstructionSecurity ListStatement of PropertiesShow All
RENOFIX 205 LEVELING MASS APPLIED ON A LIME BASE

Patination masse for smoothing internal surfaces, previously plastered with basic mortar (gypsum, lime, cement) and walls with plasterboard tiles. One bag of Renofix 205 is mixed with 7-8 liters of clean water, mixed with a mixer. The material is carefully laid, leveled and smoothed. Before gluing wall paper (carpet) or before painting, the surface must be completely dry. Store in a dry place. Durability: 6 months. It should not be used below a temperature of +5°C. Follow the technical instructions.

Technical InstructionSecurity ListStatement of PropertiesShow All
RENOFIX 220 LIGHT MORTAR WITH PERLITE FOR INTERIOR AREAS

Light layer of lime baseline for ceilings and internal concrete walls. One sack of Renofix 220 is poured into 10 toll litres of water and is mixed. The Skure-Tech S-4 is used for machine plastering afterwards levelling is required as is sanding. The thickness of the plaster should be 8 to 10 mm. The minimum functional temperature is S0C. Do not mix with other materials. Store in a dry place .

Technical InstructionSecurity ListStatement of PropertiesShow All